Sixty-one years ago tonight, a coal-cutting machine sliced through its own power cable two and a half miles underground. The arc lit a fire. The fire made smoke. And seven men learned the hard truth of every enclosed space: it isn’t the flame that kills you — it’s the air. Here’s the story, and what it still demands of you today.
On This Day in Safety — October 16, 1965 · Wilsonburg, West Virginia
Just before midnight on a Saturday, inside the Clinchfield Coal Company’s Mars No. 2 mine near Clarksburg, a continuous miner — the big machine that chews coal off the face and feeds it back onto a conveyor — cut into its own trailing power cable. The short circuit threw an arc. Fire broke out in four separate passages.
Seven men were working deep in that section. They never got a straight shot at the door.
The crew foreman, Clell Leedy, 53, led his men toward the entrance and ran straight into a wall of smoke. So they turned back, deeper into the mine, hunting for fresh air. We know this because miners carry chalk, and these men marked their path as they went — arrows, symbols, and the time beside each one. The last time they wrote down was 3:30 a.m. They found a spot, barricaded against the smoke, waited. Then they tried for another way out. The bad air caught them before they reached it.
Rescuers crawled through those tunnels for nearly 30 hours. They brought Charles Lantz, 26, out alive — he died on the way to the hospital. They found Carl Banish, 45, a father of ten, and Kenneth Kerr, 53, a father of three. And finally, behind the last fire, huddled together near the end of a tunnel, they found Leedy and three more of his crew: Ansy Kuruscz, 44; Isaac Moats, 39; and Robert Savage, 57. All seven died of suffocation. Not one died of burns.
Name it and cite it. This is MSHA country — underground coal, governed today by 30 CFR Part 75. The machine cutting its own cable is exactly why modern law demands short-circuit and ground-fault protection on trailing cables that trips the power before an arc can start a fire. The seven men dying while looking for a way out is why Part 75 now requires two separate escapeways (30 CFR 75.380) and a self-contained self-rescuer on every miner (30 CFR 75.1714) — an hour of breathable air strapped to your belt so smoke doesn’t get the last word. Mars No. 2 was one stone in a wall of 1960s coal disasters that forced the Federal Coal Mine Health and Safety Act of 1969 — the law that built the modern mine-safety system. Written in blood, every line of it. Translate it to the floor: a nicked cable, a bypassed breaker, a blocked second exit, a self-rescuer nobody checks — those aren’t paperwork. They’re the difference between walking out and leaving chalk arrows in the dark.
The Full EHS Picture
Most incidents are Environmental, Health, and Safety at once — but not every one, and we tell you straight when a dimension genuinely isn’t there. (E) This fire stayed where it started. The record shows the response was to seal the burning sections and smother them underground; there’s no documented offsite spill or airshed release — contained to the workings. (H) The health story is the whole story here: the killer was the atmosphere. Dense smoke and carbon monoxide — odorless, colorless, and faster than any flame — put all seven down. NIOSH still names CO and oxygen deficiency as the leading causes of death in mine fires, which is why gas monitoring and self-rescuers exist. One short circuit, one fire, and the gas it threw off did all the killing — H and S fused into a single failure. That’s the pattern: the thing that burns and the thing you breathe are usually the same event.
Trending Now
Two dead in a gas-unloading blast at Intel’s Kiryat Gat chip plant (Oct 14). An explosion tore through Intel’s semiconductor fab in southern Israel as trucks were unloading gas into tanks; police suspect a cylinder malfunction during the transfer. The fire involved nitrogen trifluoride (NF3), a toxic specialty gas used to clean and etch wafers. Two workers were killed and a third remains on a ventilator; all three suffered severe burns. So what for safety leaders: the connect-and-transfer moment is where compressed-gas energy is highest and attention is often lowest. If you handle specialty or toxic gases, your unloading procedure, cylinder and line integrity checks, and emergency response for a toxic release (process safety, 1910.119 territory, plus compressed-gas handling under 1910.101) deserve the same rigor as the process itself — not a tailgate afterthought.
OSHA drops $254,884 on a Pennsylvania trenching contractor (Oct 7). A young worker was engulfed installing a storm sewer 12 feet down in a trench with no cave-in protection. OSHA cited J.D. Wagoner Excavating with a willful violation for failing to protect against cave-ins, plus repeat violations for no competent-person inspections and for not pulling workers out of a known hazard. So what: cave-in protection — slope it, shore it, or box it — is required at five feet under 29 CFR 1926.652, and a competent person must inspect the trench daily and before every entry. A “willful” tag means OSHA concluded the hazard was known and the crew went in anyway. The dirt from one cubic yard can weigh as much as a small car. There is no quick in-and-out that beats that math.
Fail of the Day
Here’s one we see over and over — no names, no company, no blame, because the lesson is what matters. A maintenance tech on a packaging line grabbed a portable power cable to drag a pump into position and felt a bite — the outer jacket had a crush cut where a pallet jack had rolled over it a shift or two before, and a strand was arcing against the conductor. No one had tagged it. No one had reported it, because “it still ran fine.” He let go, shook out his hand, and got lucky: the GFCI held and tripped. Through a Just Culture lens, the question isn’t who was careless with the cord. It’s why does a damaged cable keep getting energized? Cords get run over — that’s normal in a busy bay. The system failure is that there was no easy, blameless way to pull a bad cable out of service, and no habit of looking before grabbing. Fix the system, not the person. The next guy might not have a GFCI between him and the arc.
Got a fail or a near-miss? Hit reply, or scan the QR below — we’ll feature it anonymously — no names, no company, no blame. Just the lesson, so the next crew doesn’t learn it the hard way.

Do This One Thing
Walk your cords and cables today — portable power, welding leads, trailing cables, extension cords. You’re looking for crush cuts, nicks, exposed strands, and taped “repairs.” Any cable with a damaged jacket comes out of service now, and make sure there’s a dead-simple way for anyone to red-tag it without a hassle. Then confirm the GFCI or breaker protecting that circuit actually trips when you test it. A damaged cable is just a fire waiting for an arc — and seven men in West Virginia already paid that bill for us.
🎬 Rather watch than read? Every Safety Intel story is a short video on YouTube → https://www.youtube.com/@GetSafetyIntel — subscribe so you never miss one. 📸 Share YOUR near-miss (100% anonymous): https://scantoconfess.com — or just scan the QR above. 📤 Forward this to a crew member who needs it today.